← All drills

Plexivo reliability report

Whole site lost: the Plexivo Brain detected it and rebuilt it automatically

Report
PRR-2026-017
Date
Platform release
2026.10.22
Result
Pass
Freshness
Verified · 2 days ago

Objective.

Lose every machine of a hosting site and let Plexivo rebuild it and move every resource, with no operator.

Scenario.

Every machine of a dedicated site was stopped at the provider.

Expected behaviour.

  • Declare the site lost from independent signals.
  • Build a replacement site.
  • Move every application and database to it, with its data.

Measured recovery.

Detection time
1 min 30 s
Recovery time RTO
7 min 4 s
Target 10 min · met
Recovery point RPO
0 s
Every committed write kept.
Application health
Pass
Database consistency
Pass

Customer impact.

Application availability
App answering 383 s after the loss
Management operations
Fully automatic, no operator
Data integrity
Verified
Committed data
Fully preserved

What happened.

  1. Every machine stopped.
  2. Site declared lost; replacement ordered.
  3. Replacement site active.
  4. Every resource moved.
  5. App answering.
  6. PostgreSQL and MySQL answering; every row present.

Correctness checks.

Committed data
Fully preserved

Every measurement of this drill.

Each published run of this drill, newest first
DateMeasured recoveryReport
7 min 4 sThis report
19 min 3 sView report

What we learned.

  • A whole site is rebuilt and every resource moved in about 7 minutes, with no operator.

What we changed.

  • New sites start from a prepared image: a new machine is ready for customers in about 3 minutes.
  • Every new database takes its first full backup at once, not the following night.
  • Detection confirms a lost site in 90 seconds.

Scope of this drill.

Measured with one App, one PostgreSQL and one MySQL database on a dedicated site.